HumeGard®


Gross Pollutant Trap (GPT) for Primary Stormwater Treatment

HumeGard® is a high-performance gross pollutant trap (GPT) designed to remove litter, coarse sediment and floating debris from stormwater runoff before it enters downstream waterways.

Engineered for durability, hydraulic efficiency and ease of maintenance, HumeGard® protects sensitive environments while supporting compliance with stormwater quality objectives across urban, transport and industrial catchments.

Proven Primary Treatment Performance

HumeGard® operates using physical screening, floatation and sedimentation processes to separate gross pollutants from stormwater flows.

The system incorporates:

  • An upper bypass chamber to manage high flows
  • A diversion mechanism (broad-crested weir or floating boom)
  • A protected lower holding chamber for sediment and litter capture

During low to moderate flows, treatable water is diverted into the holding sump where sediment settles and buoyant litter is retained. During peak events, excess flows bypass without disturbing previously captured material — ensuring reliable pollutant retention even under high hydraulic loads.
 

HumeGard Stormwater System Installation at Vista Residential Development

HumeGard® GPT 40B installation at Edgars Creek, Epping VIC with minimal excavation and rapid three-hour installation.

Super-Critical HumeGard® (HG12 & HG15)

Utilises a patented broad-crested weir for controlled diversion and sediment capture in compact installations.

Standard HumeGard® (HG18–HG45)

Incorporates a hinged floating boom to direct pollutants into an off-line holding chamber while maintaining full-flow bypass capability.

Designed for Durability and Long Service Life

Manufactured from high-strength precast concrete, HumeGard® units are built to perform in demanding below-ground environments. 

The system is:

  • Structurally robust for installation beneath roads and trafficable areas
  • Resistant to scour and re-suspension during high flow events
  • Designed to maintain captured pollutants during bypass conditions
  • Engineered for long-term performance with minimal operational complexity

Precast construction enables rapid installation, reduced on-site labour and consistent factory-controlled quality.

Safe and Surface-Based Maintenance

HumeGard® is designed for maintenance without confined space entry under normal operating conditions.

Routine servicing is typically performed via vacuum or eduction truck from the surface. Quarterly inspections during the first year establish the optimal cleaning frequency, with annual maintenance generally sufficient for most installations.

HumeGard® Gross Pollutant Trap (GPT) for Primary Stormwater Treatment

The HumeGard® GPT is a pollution control device that is specifically designed to remove gross pollutants and coarse sediments ≥ 150 micron from stormwater runoff.

Maintenance activities include:

  • Removal of floating litter
  • Vacuum extraction of sediment from the sump
  • Inspection of the diversion boom or weir
  • Cleaning of internal screens and chambers

Optional stainless steel baskets can be installed for interim litter removal between scheduled clean-outs.

By combining hydraulic reliability with practical maintenance access, HumeGard® supports lower whole-of-life costs and safer asset management.

Typical Applications

HumeGard® is suited to:

  • Urban development stormwater systems
  • Road and transport infrastructure
  • Commercial and industrial catchments
  • Council and municipal drainage networks
  • Sites requiring primary gross pollutant removal prior to secondary treatment

Supporting Compliance and Environmental Protection

By intercepting litter and coarse sediment upstream, HumeGard® reduces pollutant loads entering wetlands, waterways and downstream treatment systems.

The system forms an effective first line of defence in integrated stormwater management strategies and can be paired with secondary treatment devices for enhanced water quality outcomes.

Publications

07 July 2025
HumeGard HG50 Installation | Stormwater Solution with Custom In-Situ Base
A stormwater treatment project near the banks of the Parramatta River. The HumeGard® HG50 was relocated due to groundwater seepage and installed in just 3.5 hours using adjustable moulds, demonstrating adaptability and efficiency while ensuring effective
01 May 2015
HumeGard® GPT - Inspection & Maintenance Guide
The HumeGard® Maintenance Manual outlines inspection, cleaning, and servicing procedures to maintain effective stormwater treatment and extend system lifespan.
01 January 2012
HumeGard® GPT | Edgars Creek, Epping, VIC - Section 35
The HumeGard® Edgars Creek Case Study highlights the successful application of HumeGard® technology for stormwater treatment in a major urban development project.
01 January 2012
HumeGard® GPT | Federation Park, Warwick, QLD
The HumeGard® Federation Park Case Study showcases the use of HumeGard® technology to deliver effective stormwater treatment for a large residential development.
01 January 2023
HumeGard® GPT – Installation Guide | Issue 3
The HumeGard® Installation Guide details the procedures for correctly installing HumeGard® systems to ensure effective stormwater treatment and long-term performance.
01 November 2020
HumeGard® GPT – Technical Manual
The HumeGard® Technical Manual provides detailed design, specification, and performance information to support the effective application of HumeGard® systems.
01 November 2025
Vista Residential Development | HumeGard® Delivers Efficient Stormwater Solution
Humes supplied FutureCast precast HumeGard units for Vista Stage 4B-5 in Seaford Heights, SA, supporting a tight program with local manufacturing, fast lead times and reduced embodied carbon.